5V 12V DC Motor Controller For Forward Reverse Control Automatic / Speed Control / Timing / Delay / Limit H bridge Module
Descriptions:
1: Model: YYH-2 can control DC motor forward and reversing, speed, timing, spacing and other functions into one, to meet the needs of more applications.
2: Product Features: This product MOS transistor H-bridge circuit, performance, input and output opto isolated ,, as low as 0.01 seconds frequent switching, no noise, speed can be 10, well ahead of the relay contact control, relay contact point has life limit, and there was a noise, poor sensitivity, frequent contacts easily burn blocking relay contacts
3: Low power consumption: about 15ma, can be set to low-power mode, standby current of less than 10ma
4: Input voltage range and controllable power: Input voltage: DC7V~18V , output can be controlled within the motor current 7A
5: time: 0.01 seconds to 99 hours at any time adjustable
6: Speed range: a total of 10 files, the speed from 0% to 100% at any speed
7: Wiring Port Description:
IN1, IN2: signal input (active low, negative trigger sensors can be connected NPN)
DC-: power negative input
DC +: power supply positive input
M +, M-: output termination connect motor, regardless of the positive and negative level
8: Other Frequently Asked Questions: A: All settings option to automatically save the set of non-volatile content
B: But frequent on-off, performance is better than relays, than the average life expectancy is longer electromagnetic relay
9: Feature List:
P-1: the signal, forward or reverse to set the time automatically stop
F-0: to the signal 1, is to set the time automatically stopped again ,during the delay trigger is invalid
To signal 2, reversed to set the time automatically stopped again ,during the delay trigger is invalid
F-1: to the signal 1 , forward to set the time automatically stopped again, during the delay time again
To signal 2, reversed to set the time automatically stopped again ,during the delay time again
F-2: 1 to the signal, forward to set the time automatically stop, once again trigger a reset during the delay, the motor stops immediately
To signal 2, reversed to set the time automatically stop, once again trigger a reset during the delay, the motor stops immediately
P-2: with automatic forward and reversing with stop time, the reset signal 2
F-0: Auto power on an infinite loop: forward, stop, reverse, stop …. as forward reversing time, stop time, as
F-1: 1 signal to start an infinite loop: forward, stop, reverse, stop …. as forward reversing time, stop time, as
F-2: 1 initiates a signal: forward, stop, reverse, stop, do not cycle, forward and reversing the same time, stop time, as
P-3: automatic reversing without stopping time, the reset signal 2
F-0: power on automatically start an infinite loop: forward, reverse …. which may not be the same as reversing time
F-1: 1 signal to start an infinite loop: forward, reverse …. which may not be the same as reversing time
F-2: 1 initiates a signal: forward, reverse without circulation which the forward reversing time can be different
P-4: Limit function
F-0: power-forward encountered signal 1 (limit), and immediately reversed, encounter signal 2 (limit), immediately forward the cycle
F-1: power-forward encountered signal 1 (limit), stop for some time auto reverse, met signal 2 (limit), automatic stop for some time forward, recycling
F-2: power-forward encountered signal 1 (limit), stop for some time auto reverse, met signal 2 (limit), automatic stop for some time forward, not circulated
10: Brief description 🙁 key set during the automatic timing, invalid button is pressed, to prevent interference or misuse)
Mode: Press: After mode selection key P- * choose well, press the enter function K2
Short press: Set the time, set the order of: a first set of time, the second set time, set the time unit
+: When the display flashes: time plus or adjusting the first set of time units
Display not flashing: small function selection key F- *, after a good choice, press K3 into the function
-: The display flashes: Save time or adjusting the second group unit of time
Display not flashing: You can permanently turn on or off the display to reduce power consumption
Key setting explanation:
Power display “- – – -” means to enter standby state;
Press K1 for the first time, the screen displays: P-11: K2 and K3 adjust the main mode, K4 adjustment function
Press K1 for the second time, the screen shows: A001: K2 and K3 adjust the first time, K4 adjusts the decimal point (time unit)
Press K1 for the third time, the screen displays: B001: K2 and K3 adjust the second time, K4 adjusts the decimal point (time unit)
Press K1 for the fourth time, the screen displays: C001: K2 and K3 adjust the third time, K4 adjusts the decimal point (time unit)
Press K1 for the fifth time, the display “- – – – ” indicates entering the standby state;
Press K4 in standby mode to turn off/on display and switch low power mode
NOTE: Time Unit Description:
The middle two o’clock flash (about 0.2 seconds), displayed value in seconds: 0.01 seconds
Two middle slow flash (approximately 2 seconds), displayed value in hours: minutes
Two intermediate normal flash (approximately 1 second) to display the value in minutes: seconds
Speed +: Press to accelerate a file, a total of 10 stalls, the speed from 0% to 100% at any speed
Speed -: Press a gear reducer, a total of 10 stalls, the speed from 0% to 100% at any speed
نقد و بررسیها
هیچ دیدگاهی برای این محصول نوشته نشده است.